Now that we know the online SDCI request process works--better than a counter chat, in my opinion--should we seek pre-approval of the basic plan? I think so, but I want to think through the downside.
We're seeking approval for a 20' x 18.5' 370 SF workshop addition and construction of an ADU with bathroom and kitchen in the former garage. The existing bathroom and bedroom from the 1980s was apparently non-permitted, but we'll be studs out for inspection of new work and any old work that remains.
We're providing one-car off-street parking using the existing curb cut and not within the required front yard. Because we're not providing a garage, 23.44.016 F.1.a (garage closer than the house to the street) does not apply. Per 23.54.015 Table B, this space will house a "Medium vehicle, 8' x 16'" because this is a single family residence. The driveway will include an "S" turn with a 24' center radius and 12' width as required by 23.54.03 D.1.e.
Shifting the practical driveway (not the curb cut) to the east, incidentally, moves vehicular traffic away from the established Douglas Fir.
Zone: NR-1. The new addition respects the 20' front yard and 5' side yard. Actually, the west wall of the addition and ADU is at least 11' from the west property line. There is no construction in the rear yard, which is sensitive due to a steep slope into Carkeek Park.
Lot coverage is limited to 35% of parcel size of 10,600 = 3,710 SF, with an average depth of 117.65'. The existing house and non-permitted ADU is 1,706.5 SF and we're adding 370 SF for a total of 2,076.5 SF, or 19.6% of parcel size.
Our proposal is extremely respectful of neighborhood character.
![]() |
| Workshop addition shown in blue |
![]() |
| Approach from the west |
Seattle Residential Code
ASCE Design Hazards Report: Risk Category: II, Soil Class: Default, Sds=1.06, Sd1 = 0.81.
Per SRC Tabel R301.2.2.1.1, the seismic design category is D2.
- Level 1. Replacement or covering existing materials or equipment with things that serve the same purpose.
- Level 2. Add or delete door or window or installing addl equipment
- Level 3. Work area exceed 50% of the building area. [For this house, work area is 770 SF, 45.1% of 1,706.5. It's close, if "building area" excludes the ADU, we'd be at 59%.]